IEEE

IEEE/IEC P62209-1528

IEC/IEEE Draft International Standard - Recommended Practice for Measurement Procedures for the Assessment of Specific Absorption Rate (SAR) of Human Exposure to Radio Frequency Fields From Hand-Held and Body-Worn Wireless Communication Devices (Frequency Range of 4 MHz to 10 GHz)

IEEE/IEC P62209-1528

IEC/IEEE Draft International Standard - Recommended Practice for Measurement Procedures for the Assessment of Specific Absorption Rate (SAR) of Human Exposure to Radio Frequency Fields From Hand-Held and Body-Worn Wireless Communication Devices (Frequency Range of 4 MHz to 10 GHz)

Действует

Дата ввода
07.10.2020
Дата утверждения
Тип Цена
Электронная версия ( PDF ) 295.50
Печатная копия По запросу
Redline - Электронная версия ( PDF ) По запросу
Redline - Печатная копия По запросу

Наименования

IEEE/IEC P62209-1528 IEC/IEEE Draft International Standard - Recommended Practice for Measurement Procedures for the Assessment of Specific Absorption Rate (SAR) of Human Exposure to Radio Frequency Fields From Hand-Held and Body-Worn Wireless Communication Devices (Frequency Range of 4 MHz to 10 GHz)

IEEE/IEC P62209-1528 IEC / IEEE Draft International Standard - Рекомендуемая практика для процедур измерения для оценки удельного коэффициента поглощения (SAR) воздействия на человека радиочастотных полей от ручных и нательные Устройства беспроводной связи (диапазон частот от 4 МГц до 10 ГГц)

Утверждено

Информация отсутствует

Область применения

This International Standard specifies protocols and test procedures for the reproducible and conservative measurement of the peak spatial-average SAR (psSAR) induced inside a simplified model of the head or the body by radio-frequency (RF) transmitting devices, with a defined measurement uncertainty. The protocols and procedures apply to a significant majority of the population including children during the use of hand-held and body-worn wireless communication devices. These devices may include single or multiple transmitters or antennas, and may be operated with their radiating structure(s) at distances up to 200 mm from a human head or body. This standard can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, operating in conjunction with other RF-transmitting, non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The applicable frequency range is from 4 MHz to 10 GHz. Devices operating in the applicable frequency range can be tested using the phantoms and other requirements defined in this standard. The device categories covered include but are not limited to mobile telephones, cordless microphones, and radio transmitters in personal, desktop a