IEEE

IEEE/IEC 62704-1-2017

IEC/IEEE International Standard for Determining the Peak Spatial Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz. Part 1: General Requirements for using the Finite Difference Time Domain (FDTD) Method for SAR Calculations

IEEE/IEC 62704-1-2017

IEC/IEEE International Standard for Determining the Peak Spatial Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz. Part 1: General Requirements for using the Finite Difference Time Domain (FDTD) Method for SAR Calculations

Действует

Дата ввода
27.10.2017
Дата утверждения
Тип Цена
Электронная версия ( PDF ) 148.50
Печатная копия 183.00
Redline - Электронная версия ( PDF ) По запросу
Redline - Печатная копия По запросу

Наименования

IEEE/IEC 62704-1-2017 IEC/IEEE International Standard for Determining the Peak Spatial Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz. Part 1: General Requirements for using the Finite Difference Time Domain (FDTD) Method for SAR Calculations

IEEE/IEC 62704-1-2017 IEC / IEEE Международный стандарт для определения пикового пространственного среднего удельного коэффициента поглощения (SAR) в теле человека от беспроводных устройств связи, 30 МГц - 6 ГГц. Часть 1: Общие требования по использованию конечных разностей во временной области (FDTD) Метод для расчета SAR

Утверждено

Информация отсутствует

Область применения

The scope of this standard is to define the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the numerical model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the peak spatial average SAR in a cubical volume and to validate the correct implementation of the FDTD simulation software. This document will not recommend specific SAR limits since these are found elsewhere, e.g., in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) or in IEEE C95.1.

Разделы

[7] IEEE-SASB Coordinating Committees

Изменения

Информация отсутствует

Основополагающие документы

Информация отсутствует

Документ заменяют

Информация отсутствует

Документ заменил

Информация отсутствует

Основополагающие документы

Информация отсутствует