IEEE

IEEE 115-2009

IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis

IEEE 115-2009

IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis


IEEE 115-2009

IEEE Руководство по процедурам испытаний для синхронных машин Часть I & амп; mdash; Прием и тестирование производительности Часть II & амп; mdash; Процедуры испытаний и определение параметров для динамического анализа


Действует

Дата ввода
07.05.2010
Дата утверждения
Тип Цена
Электронная версия ( PDF ) 285.00
Печатная копия 352.50
Redline - Электронная версия ( PDF ) 391.50
Redline - Печатная копия 478.50

Наименования

IEEE 115-2009 IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis

IEEE 115-2009 IEEE Руководство по процедурам испытаний для синхронных машин Часть I & амп; mdash; Прием и тестирование производительности Часть II & амп; mdash; Процедуры испытаний и определение параметров для динамического анализа

Утверждено

Информация отсутствует

Область применения

This guide contains instructions for conducting generally applicable and accepted tests to determine the performance characteristics of synchronous machines. Although the tests described are applicable in general to synchronous generators, synchronous motors (larger than fractional horsepower), synchronouscondensers, and synchronous frequency changers, the descriptions make reference primarily to synchronous generators and synchronous motors. The tests described may be applied to motors and generators, as needed, and no attempt is made to partition this guide into clauses applying to motors and clauses applying to generators. It is not intended that this guide shall cover all possible tests or tests of a research nature, but only general methods that may be used to obtain performance data. The schedule of factory and field tests, which may be required on new equipment, is normally specified by applicable standards or by contract specifications. This guide should not be interpreted as requiring any specific test in a given transaction or implying any guarantee about specific performance indices or operating conditions.The term specified conditions for tests as used in this guide will be considered as rated conditions unless otherwise agreed upon. Rated conditions apply usually t

Разделы

[4] IEEE Power and Energy Society

Изменения

Информация отсутствует

Основополагающие документы

Информация отсутствует

Документ заменяют

Информация отсутствует

Документ заменил

Информация отсутствует

Основополагающие документы

Информация отсутствует