IEEE

IEEE/ANSI C57.12.24-1994

American National Standard for Transformers-- Underground-Type Three-Phase Distribution Transformers, 2500 kVA and Smaller, High Voltage, 34 500 GrdY/19 920 Volts and Below, Low Voltage, 480 Volts and Below - Requirements

IEEE/ANSI C57.12.24-1994

American National Standard for Transformers-- Underground-Type Three-Phase Distribution Transformers, 2500 kVA and Smaller, High Voltage, 34 500 GrdY/19 920 Volts and Below, Low Voltage, 480 Volts and Below - Requirements


IEEE/ANSI C57.12.24-1994

Американский национальный стандарт для Transformers-- Underground-трехфазных распределительных трансформаторов, 2500 кВА и меньше, высокое напряжение, 34 500 GrdY / 19 920 вольт и ниже, низкое напряжение, 480 вольт и ниже - Требования


Не действует

Дата ввода
24.05.1994
Дата утверждения
Тип Цена
Электронная версия ( PDF ) 79.50
Печатная копия По запросу
Redline - Электронная версия ( PDF ) По запросу
Redline - Печатная копия По запросу

Наименования

IEEE/ANSI C57.12.24-1994 American National Standard for Transformers-- Underground-Type Three-Phase Distribution Transformers, 2500 kVA and Smaller, High Voltage, 34 500 GrdY/19 920 Volts and Below, Low Voltage, 480 Volts and Below - Requirements

IEEE/ANSI C57.12.24-1994 Американский национальный стандарт для Transformers-- Underground-трехфазных распределительных трансформаторов, 2500 кВА и меньше, высокое напряжение, 34 500 GrdY / 19 920 вольт и ниже, низкое напряжение, 480 вольт и ниже - Требования

Утверждено

Информация отсутствует

Область применения

1.1 This standard is intended to set forth characteristics relating to performance, limited electrical and mechanical interchangeability, and safety of the equipment described, and to assist in the proper selection of such equipment.NOTE — Refer to the latest Federal Regulations concerning polychlorinated biphenyls (PCB) contamination in transformers.1.2 This standard describes certain electrical and mechanical characteristics and takes into consideration certain safety features of three-phase, 60-Hz, liquid-immersed, self-cooled, underground-type distribution transformers rated 2500 kVA and smaller with high voltages of 34 500GrdY/19 920 volts and below and with low voltages of 480 volts and below. These transformers are generally used for step-down purposes from an underground primary cable supply and are suitable for occasional submerged operation.1.3 This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.

Разделы

IEEE [4] IEEE Power and Energy Society

Изменения

Информация отсутствует

Основополагающие документы

Информация отсутствует

Документ заменяют

Информация отсутствует

Документ заменил

Информация отсутствует

Основополагающие документы

Информация отсутствует